Black Friday Sale, Up to 12% Off Storewide || Use Code:  BF2026   || TWO FREE Remotes with all APC Gate Automation Kits RRP$110 (Excluding Motorline & Roger Technology) || FREE Shipping on orders above $1199* (except Freight Items & PO Box deliveries) || Australian Owned and Operated. Serving Aussie Homes & Businesses Since 2004. Gate Automation and Intercom, Automatic Electric Gate Openers & Video Intercom Packages & Gate Automation and Intercom Combos & Customised Gate Automation Kit Builders

Cart 0

Get More Info

Product SKU: WLB-V-W-LD-LI-CPT50

Complete Package for Automatically Controlling The Flashing Warning Light With eLoop Radar Detector. Warning Light Controller with Flashing Warning Light/Buzzer and Integrated Antenna, e-Loop Detector Combo | Universal LED warning flashing light, multi-mode, Universal LED flashing light with integrated audio buzzer warning sound | Made in Italy

Upload Images (Max. 5 images can be uploaded)

Upload
no file chosen

Complete Package for Automatically Controlling The Flashing Warning Light With eLoop Radar Detector. Warning Light Controller with Flashing Warning Light/Buzzer and Integrated Antenna, e-Loop Detector Combo | Universal LED warning flashing light, multi-mode, Universal LED flashing light with integrated audio buzzer warning sound | Made in Italy

Product SKU: WLB-V-W-LD-LI-CPT50

  •  In Stock

Get More Info..
Free Shipping Free Shipping

Kit Price:

$1,499.00

  • Or in 4 payment of $374.75 with afterpay info
  • Italian Made Flashing Warning Lights With Buzzer and Antena Connection| LED Lights | 12V / 24V / 220V

  • Kit Includes

    01 Versatile Traffic Lights Management Electronic Controller | Dual Traffic Light Control | Ideal for Alternating One-Way Roads | Made in Italy by Stagnoli | 24V Traffic Flow Control with 2 Lights Suitable for Solar Application | Perfect for Alternating One-Way Roads in Apartments, Ramps, and Car Parks | ACNSEM3L-24V (QTY: 1)
    02 Universal Flashing Warning Lights With Buzzer and Antenna Connection | Universal LED flashing light with integrated audio buzzer warning sound | Made in Italy | Rating IP65| (QTY: 1)
    03 e-Loop Light Industrial Wireless Vehicle Detector with Exit and Presence Mode and Dual Sensor Technology, Magnetic Field and Radar Detection | Commercial Wireless Vehicle Ground Loop Sensor System Designed for Easy Above-Ground Mounting, No Need for Cable (QTY: 1)
    04 E-Trans-50 (V4) Single Channel Transceiver | Wireless Vehicle Detection Loop System | 12-24VDC (QTY: 1)
    05 APC Power Convertor 16-28V AC/DC In to 12V DC Output (QTY: 1)
    06 Weatherproof External 24V Transformer with 20m Low Voltage Cable | Suitable for outdoor use. (QTY: 1)
  • Customise Kit
  • Add-On Items
  • Product Information

Customise your Kit

Upgrades are available for following items

Add-On Items (Discounted when purchased along with this Kit)

Product Information

Traffic Controller, e-Loop, Flashing Light With Buzzer Wiring Diagram

Note: Power supply should be 24 Volts DC

 

Traffic Light Controller for Two-Lights and 2 or 3 Light Lens | 24v ACNSEM3L Made in Italy by Stagnoli

Control board for 2 traffic lights with 2 or 3 lights. Specially designed for alternating one-way roads in apartment buildings (e.g. ramps), company and car park contexts. The ACNSEM3L universal electronic control unit has been a solution for managing two or three traffic lights with two or three lenses in situations where access driveways are narrow and require alternate transit (garage, parking, residence, etc.).

It can be programmed to operate cyclically or logically (e.g. when used with external sensors).

Highlights

  • One Board for Two Trafic Lights
  • Time-based work method
  • Priority-based work method

 

Specifications and Wiring Diagram

Power: 24Vac/dc
Max Power Current: 0,5 A
Operating Temperature: -20°C to 60°C
Max Lights Power Current: 2A
 

 

Control Board Overview

1. Terminal board for power supply 24Vac/dc
2. Power supply and accessories fuse (T0,5A, 5x20)
3. Traffic light 2 terminal board
4. Traffic light 1 terminal board
5. Traffic lights management fuse (F2A 5x20)
6. Priorities input terminal board, with control devices (photocells, detection devices, etc.):
     IN1: programmable input for traffic light 1, N.O. by default
     IN2: programmable input for traffic light 2, N.O.by default
     IN3: emergency programmable input, N.C. by default
7. Auxiliary power supply 24Vac/dc 0,5 A
8. Menu navigation buttons
9. 5-language LCD display (IT, EN, FR, DE, ES)
     DL2- Traffic light operation 1
     DL1- Traffic light operation 2

Universal LED Warning Flashing Light, Integrated Audio Buzzer.

Flashing Warning Lights With Buzzer

Universal LED Flashing Warning Lights With Buzzer

6-LED Flashing light with high efficiency and low power consumption. Universal power supply, 12V – 24V and 230V.

This flashing light with an audio buzzer (beacon light warning alarm/siren) consumes about 93% less energy than traditional indicators, and the LED's lifespan is about 50 times longer than conventional incandescent lamps. The Flashing Warning Light with Warning Buzzer comes with a wall-mounting bracket, is easy to install, and has an IP65 degree of protection. The Warning Light allows you to select the type of light (steady or flashing) with a jumper on the board. 

 

Dimensions and Technical Data - Universal LED Warning Flashing Light

Operating temperature: -20°C, +50°C

 

 

 

e-Loop Light Industrial Wireless Vehicle Detector — Exit & Presence Mode (Version 4)

Model: EL00LI | Category: Wireless Vehicle Detection | Available in Australia

The e-Loop Light Industrial (model EL00LI) is a professional-grade, battery-powered wireless vehicle detector engineered for continuous use in demanding light industrial environments across Australia. Designed to replace traditional inductive loop detectors without ground cutting or cabling, it provides accurate, reliable vehicle detection for driveways, loading bays, factory gates, service yards and logistics centres. With support for three operational modes — Exit Mode, Presence Mode and Parking Mode — the e-Loop Light Industrial delivers the flexibility required across a wide range of gate automation and vehicle access control applications.

 

Enclosed in a rugged grey housing with an IP68 ingress protection rating and an operating temperature range of −40°C to +80°C, this sensor is built to perform reliably in Australia's diverse and demanding climate conditions — from the tropical north to alpine and desert environments. Its advanced auto-calibration technology and 128-bit AES-encrypted wireless transmission ensure precise, secure operation with minimal maintenance, making it a true set-and-forget detection solution.

 

Key Features of the e-Loop Light Industrial Wireless Vehicle Detector

  • Three Operational Modes: Supports Exit Mode (single trigger pulse on vehicle detection), Presence Mode (latches relay whilst vehicle is present, keeping gates open), and Parking Mode (slower latch/release with reduced power draw) — selectable by magnet or via the e-Loop Connect app.
  • Completely Wireless & Battery-Powered: No ground cutting, no trenching, no cabling required. Powered by 4 × 3.6V 2700mAh batteries, enabling quick installation with zero surface disruption.
  • IP68 Ingress Protection: Fully sealed against dust and water ingress for reliable outdoor performance in all Australian weather conditions, including heavy rain and flooding risk environments.
  • Dual-Technology Detection (Radar + Magnetometer): Combines radar sensing (up to 2 m range, 60° field of view) with a tiered magnetometer for highly accurate, false-trigger-resistant vehicle detection.
  • 128-Bit AES Encryption: All wireless signals between the sensor and receiver are encrypted with 128-bit AES, ensuring tamper-resistant, secure data transmission.
  • Set-and-Forget Auto-Calibration: The e-Loop continuously self-calibrates to adapt to environmental changes. After mounting, it will automatically calibrate within 5 minutes, or it can be manually calibrated using the included magnet.
  • 433.39 MHz FSK Wireless Communication: Operates on the 433 MHz band with FSK modulation, providing stable, long-range signal transmission compatible with the full e-Trans receiver range.
  • e-Loop Connect App Compatible: Access advanced diagnostics, mode changes, confirmation mode settings and radar range adjustments via the free e-Loop Connect mobile app for Android and iPhone.
  • Extreme Temperature Tolerance: Operates reliably across −40°C to +80°C, suitable for Australian environments from tropical Queensland to cold southern regions.
  • Rapid, Low-Disruption Installation: Above-ground mounting with included fasteners to a clean, flat, level surface — no specialist tools or contractors required.
  • EN 301 489-1 V2.2.3 & EN 55032 Compliant: Manufactured and tested to international EMC radio compliance standards.
  • Confirmation Mode: Optional confirmation mode reduces false triggers, providing additional confidence in gate automation applications.

 

Full Product Description — e-Loop Light Industrial Wireless Vehicle Detector

Purpose-Built for Australian Light Industrial Environments

The e-Loop Light Industrial is engineered to meet the rigorous demands of commercial and light industrial operations across Australia. Unlike traditional inductive loop detectors that require cutting into the road surface and extensive cabling, the EL00LI sensor mounts above the ground and communicates wirelessly — eliminating costly installation work and surface damage. This makes it an ideal solution for retrofitting existing facilities or deploying quickly in new sites where operational continuity is critical.

 

Its grey, durable housing is designed to withstand the mechanical stress of continuous vehicle drive-overs, maintaining structural integrity under the daily loads of trucks, forklifts, and industrial vehicles. With an IP68 ingress protection rating, the sensor is fully protected against dust and water, delivering consistent performance regardless of Australian weather conditions.

 

Exit Mode, Presence Mode & Parking Mode Explained

One of the defining characteristics of the e-Loop Light Industrial is its support for three distinct operational modes, each tailored to a different vehicle management scenario:

Exit Mode delivers a single momentary trigger pulse to the paired e-Trans receiver when a vehicle enters the detection zone. This is the standard configuration for driveway exit sensors and vehicle exit detectors — signalling a gate or barrier to open as a vehicle approaches to leave a site. The gate then closes on its normal timer or safety edge signal. Exit Mode is the most common configuration for automated gate systems at industrial sites, warehouses, and logistics centres across Australia.

Presence Mode sends a continuous pulse and latches the relay output, holding the gate or barrier open for the entire duration that a vehicle is detected within the sensor's zone. When the vehicle clears the area, the relay releases, allowing the gate to close. This mode is ideal for loading dock management, where vehicles must be stationary for extended periods during loading and unloading, and the gate or door must remain securely open throughout. It is important to note that Presence Mode is designed for vehicle detection only and should not be used as a personal safety device for pedestrian protection.

Parking Mode operates on the same principle as Presence Mode — latching the relay when a vehicle is detected — but features slower latch and release speeds, making it better suited to lower-traffic parking and storage areas. It also consumes less power, extending battery life in applications with longer dwell times.

Modes can be changed at any time using the included magnet on the sensor's magnetic recesses or remotely using the e-Loop Connect mobile app, available free for both Android and iPhone devices. The app also enables access to advanced diagnostics, radar range adjustment, and confirmation mode — providing complete remote management without the need to physically access the sensor.

 

Wireless Technology & Secure Transmission

The e-Loop Light Industrial transmits over the 433.39 MHz FSK frequency band with a nominal output power of 14 dBm. All transmissions are encrypted with 128-bit AES encryption, preventing signal interception, cloning, or replay attacks — a critical feature for security-sensitive industrial sites. The system is compatible with the full range of e-Loop e-Trans receivers (e-Trans 20, 50, 100 and 200), which provide standard relay outputs for integration with existing gate controllers, access control systems and barrier operators commonly used across Australian commercial and industrial facilities.

Pairing with an e-Trans receiver can be performed in two ways: short-range coding by holding the magnet on the e-Loop's code recess while pressing the code button on the nearby e-Trans unit, or long-range coding for situations where the transmitter and receiver are already deployed at a distance.

 

Intelligent Auto-Calibration

The e-Loop Light Industrial features adaptive auto-calibration that continuously monitors and adjusts to the electromagnetic environment surrounding the sensor. This eliminates false triggers caused by changes in ground composition, nearby metalwork, or environmental drift, which commonly affect fixed inductive loops. After installation on a clean, flat, level surface, the sensor will automatically calibrate within approximately 5 minutes. If the sensor is relocated, a manual recalibration procedure is required using the included magnet — a simple three-step process that takes only seconds.

 

Optimal Mounting for Maximum Detection Performance

To achieve consistent and reliable detection, the e-Loop Light Industrial should be mounted centrally on the most frequently driven path, with the directional arrow facing toward the gate. The mounting surface must be clean, flat, and level — uneven terrain, debris, or rocks can compromise calibration accuracy and risk physical damage to the housing. The unit should not be mounted in areas prone to flooding without adequate drainage, near high-voltage cables, or in proximity to strong electromagnetic interference sources. The sensor must be firmly secured with the provided fasteners and must not move once installed.

 

Benefits of the e-Loop Light Industrial for Australian Businesses

Eliminate Costly Ground Works
Traditional inductive loop detectors require saw-cutting the road surface, embedding loop wire, filling and sealing the cut, and running conduit to a control panel. The e-Loop Light Industrial requires none of this — delivering significant cost savings on installation, particularly relevant for existing facilities in Australia where resurfacing work is expensive and disruptive.
Zero Operational Downtime During Installation
Because the e-Loop mounts above ground and requires no electrical connection to the site's power infrastructure, installation can typically be completed in under an hour without closing the facility or disrupting vehicle flow. This is particularly valuable for high-throughput logistics centres, warehouses and factories that operate around the clock.
Flexible Mode Selection for Multiple Use Cases
A single product model supports Exit, Presence and Parking modes — meaning one SKU can address multiple detection scenarios across your site. Modes can be changed remotely via the app, avoiding the need to replace hardware as operational requirements evolve.
Secure, Encrypted Signal Transmission
128-bit AES encryption on all wireless communications ensures that the vehicle detection system cannot be compromised by signal interception or spoofing — providing confidence for security-conscious industrial and commercial facilities.
Reduced Maintenance Burden
Set-and-forget auto-calibration means the sensor continually adapts to its environment without operator intervention, reducing the maintenance overhead associated with traditional inductive loop systems which are prone to detuning, wire breaks, and false triggers over time.
App-Based Remote Diagnostics
The e-Loop Connect app gives operators visibility of battery level, signal strength, current mode, and diagnostic data — enabling proactive maintenance and rapid fault identification without dispatching a technician to site.
Rugged Design for Australian Conditions
IP68 ingress protection and a −40°C to +80°C temperature range ensure the sensor performs in Australia's extreme and varied climate, from tropical humidity in Darwin and Cairns to summer heat in Western Australia and winter frosts in Victoria and Tasmania.

 

Technical Specifications — e-Loop Light Industrial (EL00LI)

Full Technical Datasheet: e-Loop Light Industrial Wireless Vehicle Detector (Model EL00LI)

Power, Physical & Environmental

Specification Detail
Model ID EL00LI
Power Source 4 × 3.6V 2700mAh batteries
Activation Power Draw 40 µA
Standby Power Draw 14 µA
Operating Temperature −40°C to +80°C
Ingress Protection IP68 (fully dust and water sealed)
Mounting Environment Above-ground surface mount
Dimensions 224 × 224 × 36 mm
Battery Life Up to 6 Years

 


Note: Battery Life is dependent on many factors, including daily activations, time used per activation, radar range & external conditions

 

 

Radio & Communication

Specification Detail
Frequency 433.39 MHz
Modulation FSK (Frequency Shift Keying)
Bit Rate 100 kbps
Bandwidth 50 kHz
Nominal Output Power 14 dBm
Receive Sensitivity −126.2 kHz
Antenna Type PCB
Encryption 128-bit AES

 

Spurious Emissions

Specification Detail
30 MHz – 1,000 MHz < −56 dBm
1 GHz – 12.75 GHz < −44 dBm
1.8 GHz – 1.9 GHz < −56 dBm
5.15 GHz – 5.3 GHz < −51 dBm

 

 

Radar Detection

Specification Detail
Field of View (FOV) 60°
Dead Zone (minimum) 0.2 m
Minimum Read Distance 0.7 m
Default Read Distance 1.8 m
Maximum Read Distance 2.0 m

 

 

Magnetometer Detection Zones

Specification Detail
Low Detection Range 1.5 m (bidirectional)
Medium Detection Range 1.0 m (bidirectional)
High Detection Range 0.5 m (bidirectional)

 

 

Operational Modes

Specification Detail
Exit Mode Sends a single momentary pulse trigger to the receiver upon vehicle detection
Presence Mode Pulses and latches relay, holding the gate open whilst the loop is detecting a vehicle
Parking Mode Same behaviour as Presence Mode; slower latch, slower release, lower power consumption
Default Mode Presence Mode
Mode Change Method Magnetic recess interaction (included magnet) or e-Loop Connect mobile app

 

Compliance

Specification Detail
EMC Standard EN 301 489-1 V2.2.3 — ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for EMC
Emissions Standard EN 55032 — Electromagnetic compatibility of multimedia equipment

 

App & Connectivity

Specification Detail
Mobile App e-Loop Connect (available for Android and iPhone)
App Functions Mode change, radar range adjustment, confirmation mode, diagnostics, battery status, signal strength
Bluetooth BLE (Bluetooth Low Energy) for app connection

Compatible Receivers

Specification Detail
e-Trans Compatibility e-Trans 20, e-Trans 50, e-Trans 100, e-Trans 200

 

Common Applications for the e-Loop Light Industrial in Australia

  • Industrial Driveway Exit Detection: Triggers automatic gates and barriers to open as vehicles approach to exit an industrial site, warehouse, or logistics facility.
  • Loading Bay Presence Detection: Holds roller doors and dock levellers open while trucks are present at the loading dock, preventing premature closure during loading and unloading operations.
  • Factory Perimeter Gate Automation: Provides vehicle-triggered gate automation at factory access points, eliminating the need for manual gate operation or surface-mounted loop wire.
  • Service Yard Entry and Exit Management: Monitors vehicle arrivals and departures at service yards, fuel depots, and maintenance facilities.
  • Logistics Centre Vehicle Flow Control: Manages traffic flow through multi-gate logistics facilities with individual zone control via separate e-Trans receivers.
  • Warehousing Facility Gate Triggers: Automates internal and perimeter gate operation in multi-tenant warehousing estates.
  • Mining Site Access Control: Rugged construction and extreme-temperature tolerance suit remote Australian mining-site environments.
  • Agricultural & Rural Property Gates: A battery-powered, wireless design is ideal for remote rural properties in Australia without mains power at the gate.
  • Car Park Exit Lane Detection: Detects vehicles at pay station exit lanes or boom gate approaches in commercial car parks.
  • Retrofit of Existing Inductive Loop Systems: Directly replaces failed or outdated saw-cut inductive loop detectors without requiring road surface works.

 

Installation Overview — How to Set Up the e-Loop Light Industrial

The e-Loop Light Industrial is designed for quick, straightforward above-ground installation. The following is a summary of the setup process. For complete step-by-step instructions, refer to the Instruction Manual.

  1. Step 1 — Coding / Pairing with e-Trans Receiver: Use either short-range coding (hold magnet on CODE recess of e-Loop while pressing the CODE button on the e-Trans receiver until LEDs confirm pairing) or long-range coding (hold magnet until Yellow LED flashes, then activate the e-Trans CODE button) to wirelessly pair the sensor with its receiver.
  2. Step 2 — Mounting: Clean the desired mounting location of all dirt and debris. Mount the e-Loop on a clean, flat, level surface in the centre of the most frequently driven path. Ensure the directional arrow faces toward the gate. Secure firmly using the included fasteners. Reinstall dust caps on all screw holes. Do not mount near high-voltage cables, on uneven terrain, in flood-prone areas without drainage, or on irregular or sharp ground surfaces.
  3. Step 3 — Calibration: Remove all metallic objects from the vicinity. Hold the magnet in the SET recess until the Red LED flashes twice, then remove the magnet. The e-Loop will calibrate within approximately 5 seconds, confirmed by 3 Red LED flashes. If the sensor is moved after calibration, it must be recalibrated. Alternatively, the unit will self-calibrate automatically within 5 minutes if left undisturbed.
  4. Step 4 — Mode Selection (Optional): The default mode is Presence Mode. To change to Exit or Parking Mode, use the included magnet on the appropriate magnetic recess or use the e-Loop Connect app. Refer to the instruction manual for the LED confirmation sequences for each mode.

Important Installation Warnings: Always install in accordance with the fitment notes in the instruction manual. Failure to do so may void the product warranty. The e-Loop Light Industrial should not be used in Presence Mode as a personal safety device — it is designed exclusively for vehicle detection.

 

 

Frequently Asked Questions — Wireless Vehicle Detector (Australia)

What is a wireless vehicle detector, and how does it work?

A wireless vehicle detector is a sensor that identifies the presence or movement of a vehicle and transmits a trigger signal wirelessly — without physical wiring — to a receiver or gate controller. The e-Loop Light Industrial uses a combination of radar sensing and magnetometer technology. When a vehicle enters the detection zone, the sensor detects the vehicle's mass and metallic signature, encrypts the trigger signal using 128-bit AES, and transmits wirelessly to the paired e-Trans receiver at 433.39 MHz FSK, which then activates the relay output to open a gate, barrier, or trigger an alert.

What is the difference between Exit Mode and Presence Mode on the e-Loop Light Industrial?

Exit Mode sends a single momentary pulse to the receiver when a vehicle is detected — ideal for triggering a gate to open as a vehicle approaches to exit a site. Presence Mode sends a continuous pulse and latches the relay, holding the gate open for as long as the vehicle remains within the detection zone — suited to loading docks and areas where the gate must stay open during vehicle dwell time. Parking Mode is similar to Presence Mode, with a slower latch/release and lower power consumption, making it better suited to parking and storage applications.

Does the e-Loop Light Industrial require any wiring or ground cutting to install?

No. The e-Loop Light Industrial is completely wireless and battery-powered, requiring no ground cutting, no trenching, and no electrical wiring. It mounts above ground using the included fasteners and communicates wirelessly with compatible e-Trans receivers. This makes it ideal for retrofitting existing driveways, loading docks or factory gates without disrupting the surface or operational flow.

Is the e-Loop Light Industrial suitable for outdoor use in Australian conditions?

Yes. The EL00LI carries an IP68 ingress protection rating — fully sealed against dust and continuous water immersion — and operates across an extreme temperature range of −40°C to +80°C. This makes it well-suited to Australia's varied climate conditions across all states and territories, including tropical, arid, alpine and temperate zones.

What is the wireless detection range of the e-Loop Light Industrial?

The radar detection system provides a 60° field of view with a default read distance of 1.8 m, a maximum range of 2.0 m, and a minimum read distance of 0.2 m. The magnetometer provides tiered detection sensitivity at 0.5 m, 1.0 m and 1.5 m ranges. Wireless radio transmission range between the sensor and the paired e-Trans receiver depends on site conditions and the selected e-Trans model.

How long do the batteries last in the e-Loop Light Industrial?

Battery life is influenced by daily activation frequency, activation duration, radar range setting, and environmental conditions. The unit is powered by 4 × 3.6V, 2700 mAh batteries with an extremely low standby draw of just 14 µA. At 50 activations per day, battery life is substantially longer than at higher activation frequencies, such as 300+ per day. The e-Loop Connect app provides real-time battery status diagnostics.

Can I change the operating mode after installation without removing the sensor?

Yes. Mode changes are made in two ways: physically using the included magnet on the sensor's magnetic recesses (no tools required), or remotely via the free e-Loop Connect mobile app for Android and iPhone. The app also enables radar range adjustment, confirmation mode configuration, and access to diagnostics — all without physically interacting with the sensor.

Does the e-Loop require recalibration if moved to a different location?

Yes. Once calibrated, the e-Loop requires recalibration whenever it is physically moved to a new location. Recalibration is performed using the included magnet on the SET recess in a simple three-step process. If the sensor is not moved, it will automatically self-calibrate within approximately 5 minutes of being powered on.

Is the e-Loop Light Industrial compatible with existing gate automation systems in Australia?

The e-Loop Light Industrial pairs with e-Loop's e-Trans receiver range (e-Trans 20, 50, 100 and 200), which provides standard relay outputs for integration with most gate automation controllers, barrier systems, and access control panels commonly used across Australian commercial and industrial sites. Always confirm relay output compatibility with your specific gate controller or automation brand before purchasing.

What applications is the e-Loop Light Industrial suited to in Australia?

The EL00LI is suited to a broad range of Australian applications including: driveway exit detection for industrial estates, loading bay presence monitoring, factory perimeter gate automation, service yard entry and exit control, logistics centre vehicle flow management, warehousing gate triggers, mining site access control, rural property gate automation, car park exit detection, and retrofit replacement of failed inductive loop detectors.

What is the model number of the e-Loop Light Industrial, and where can I find the instruction manual?

The model number is EL00LI. The full instruction manual is available for download in PDF format from Installation Manuals

Is the e-Loop Light Industrial compliant with Australian standards?

The e-Loop Light Industrial is tested and certified to EN 301 489-1 V2.2.3 (ElectroMagnetic Compatibility standard for radio equipment) and EN 55032 (Electromagnetic compatibility of multimedia equipment emissions).

Can the e-Loop Light Industrial be used as a pedestrian or personal safety device?

No. The e-Loop Light Industrial is designed exclusively for vehicle detection. It must not be used as a personal safety device for pedestrian protection. Presence Mode in particular — which holds a gate open while detecting mass — is not a substitute for safety edges, photocells or other certified personal safety devices required by Australian Standards for automated gate systems.

 

 

E-Trans-50 Single Channel Transceiver

Wireless access control system for gate and door applications.

Featuring a compact design with exceptional range, the e-Trans-50 is designed to manage access control for home and commercial systems.

A long-range wireless transceiver that can work with both gates and automatic doors. The small design allows it to be easily installed without compromising on the exceptional range.

 

Specifications

Voltage: 10-36V DC

Current draw standby: 4.5 m/a

Current draw active: 30 m/a

Frequency: 433.39 MHz

Remote storage: 50 remotes, 4 x e-Loops, 4 x keypads, 4 x entry buttons

Relay: 1-amp contact rating, COM and N/O connections x 1 relay

Modes: Pulse, Latch and Hold

 

FEATURES

  • Compact design with an exceptional range

  • SMA connector standard for external long-range antenna connection

  • Wide Voltage Range: 10-36V DC

  • Exceptionally low Current draw: standby 4.5 m/a, active 30 m/a

  • Frequency: 433.39 MHz

  • Remote storage: 50 remotes, 2 x Keypads, 2 x Entry Buttons

  • Relay: 1-amp contact rating, COM and N/O connections x 1 relay

  • Multiple Modes: Pulse, Latch and Hold

 

 

12V DC Power Converter

12V DC Power Convertor

12V DC Power Converter
Specifications  

Input voltage: AC & DC 16-28V
Output voltage: DC 12V
Output current: 500mA
Operating temperature: -10° C~55° C (-14~131° F)
Operating humidity: 0-90%
Dimension: 73mm × 40mm × 23mm

   

 

 

External Transformer (Extendable up to 80 metres cable distance)

24V External weatherproof designed to be used in a low voltage cabling application of up to 80 meters, supplied with a pre-connected 20-meter cable. This is a perfect solution when running mains power to the gate is not viable due to costs, difficulty or simply to DIY.

 

 

Specifications

Type: Remote External Transformer 

Input voltage: 240V AC

Output Voltage: Low Voltage 24v AC

Amperage: 10A

Input connection: Plug With 1m 240AC Pre-Connected Cable

Output connection: 20m Pre-Connected Cable (Extendable up to 80 metres)

Suitability: Outdoor use, 10amp Power-Point

 

Your Customised Kit Includes:

No Changes.
        • Kit Quantity:
          • 1
        • Your (Kit and Add-On) Price:

          $1,499.00

        Have Questions?Talk to the Experts1800 694 283

        Dispatched in: Within One
        Business Day