Black Friday Sale, Up to 12% Off Storewide || Use Code: BF2026 || TWO FREE Remotes with all APC Gate Automation Kits RRP$110 (Excluding Motorline & Roger Technology) || FREE Shipping on orders above $1199* (except Freight Items & PO Box deliveries) || Australian Owned and Operated. Serving Aussie Homes & Businesses Since 2004.
, Automatic Electric Gate Openers & Video Intercom Packages & Gate Automation and Intercom Combos & Customised Gate Automation Kit Builders
Looks like you have not added anything to the cart. Go ahead & explore top categories.
ON SALE
Product SKU: W-LD-LI-CPT50
In Stock
Product SKU: W-LD-LI-CPT50
e-Loop (V4) Wireless Vehicle Detection | Exit and Presence Mode | Dual Sensor (Magnetic Field & Radar Detection)
Model: EL00LI | Category: Wireless Vehicle Detection | Available in Australia

Enclosed in a rugged grey housing with an IP68 ingress protection rating and an operating temperature range of −40°C to +80°C, this sensor is built to perform reliably in Australia's diverse and demanding climate conditions — from the tropical north to alpine and desert environments. Its advanced auto-calibration technology and 128-bit AES-encrypted wireless transmission ensure precise, secure operation with minimal maintenance, making it a true set-and-forget detection solution.

Its grey, durable housing is designed to withstand the mechanical stress of continuous vehicle drive-overs, maintaining structural integrity under the daily loads of trucks, forklifts, and industrial vehicles. With an IP68 ingress protection rating, the sensor is fully protected against dust and water, delivering consistent performance regardless of Australian weather conditions.
One of the defining characteristics of the e-Loop Light Industrial is its support for three distinct operational modes, each tailored to a different vehicle management scenario:
Exit Mode delivers a single momentary trigger pulse to the paired e-Trans receiver when a vehicle enters the detection zone. This is the standard configuration for driveway exit sensors and vehicle exit detectors — signalling a gate or barrier to open as a vehicle approaches to leave a site. The gate then closes on its normal timer or safety edge signal. Exit Mode is the most common configuration for automated gate systems at industrial sites, warehouses, and logistics centres across Australia.
Presence Mode sends a continuous pulse and latches the relay output, holding the gate or barrier open for the entire duration that a vehicle is detected within the sensor's zone. When the vehicle clears the area, the relay releases, allowing the gate to close. This mode is ideal for loading dock management, where vehicles must be stationary for extended periods during loading and unloading, and the gate or door must remain securely open throughout. It is important to note that Presence Mode is designed for vehicle detection only and should not be used as a personal safety device for pedestrian protection.
Parking Mode operates on the same principle as Presence Mode — latching the relay when a vehicle is detected — but features slower latch and release speeds, making it better suited to lower-traffic parking and storage areas. It also consumes less power, extending battery life in applications with longer dwell times.
Modes can be changed at any time using the included magnet on the sensor's magnetic recesses or remotely using the e-Loop Connect mobile app, available free for both Android and iPhone devices. The app also enables access to advanced diagnostics, radar range adjustment, and confirmation mode — providing complete remote management without the need to physically access the sensor.
The e-Loop Light Industrial transmits over the 433.39 MHz FSK frequency band with a nominal output power of 14 dBm. All transmissions are encrypted with 128-bit AES encryption, preventing signal interception, cloning, or replay attacks — a critical feature for security-sensitive industrial sites. The system is compatible with the full range of e-Loop e-Trans receivers (e-Trans 20, 50, 100 and 200), which provide standard relay outputs for integration with existing gate controllers, access control systems and barrier operators commonly used across Australian commercial and industrial facilities.
Pairing with an e-Trans receiver can be performed in two ways: short-range coding by holding the magnet on the e-Loop's code recess while pressing the code button on the nearby e-Trans unit, or long-range coding for situations where the transmitter and receiver are already deployed at a distance.
The e-Loop Light Industrial features adaptive auto-calibration that continuously monitors and adjusts to the electromagnetic environment surrounding the sensor. This eliminates false triggers caused by changes in ground composition, nearby metalwork, or environmental drift, which commonly affect fixed inductive loops. After installation on a clean, flat, level surface, the sensor will automatically calibrate within approximately 5 minutes. If the sensor is relocated, a manual recalibration procedure is required using the included magnet — a simple three-step process that takes only seconds.
To achieve consistent and reliable detection, the e-Loop Light Industrial should be mounted centrally on the most frequently driven path, with the directional arrow facing toward the gate. The mounting surface must be clean, flat, and level — uneven terrain, debris, or rocks can compromise calibration accuracy and risk physical damage to the housing. The unit should not be mounted in areas prone to flooding without adequate drainage, near high-voltage cables, or in proximity to strong electromagnetic interference sources. The sensor must be firmly secured with the provided fasteners and must not move once installed.
Full Technical Datasheet: e-Loop Light Industrial Wireless Vehicle Detector (Model EL00LI)
| Specification | Detail |
|---|---|
| Model ID | EL00LI |
| Power Source | 4 × 3.6V 2700mAh batteries |
| Activation Power Draw | 40 µA |
| Standby Power Draw | 14 µA |
| Operating Temperature | −40°C to +80°C |
| Ingress Protection | IP68 (fully dust and water sealed) |
| Mounting Environment | Above-ground surface mount |
| Dimensions | 224 × 224 × 36 mm |
| Battery Life | Up to 6 Years |

Note: Battery Life is dependent on many factors, including daily activations, time used per activation, radar range & external conditions
| Specification | Detail |
|---|---|
| Frequency | 433.39 MHz |
| Modulation | FSK (Frequency Shift Keying) |
| Bit Rate | 100 kbps |
| Bandwidth | 50 kHz |
| Nominal Output Power | 14 dBm |
| Receive Sensitivity | −126.2 kHz |
| Antenna Type | PCB |
| Encryption | 128-bit AES |
| Specification | Detail |
|---|---|
| 30 MHz – 1,000 MHz | < −56 dBm |
| 1 GHz – 12.75 GHz | < −44 dBm |
| 1.8 GHz – 1.9 GHz | < −56 dBm |
| 5.15 GHz – 5.3 GHz | < −51 dBm |
| Specification | Detail |
|---|---|
| Field of View (FOV) | 60° |
| Dead Zone (minimum) | 0.2 m |
| Minimum Read Distance | 0.7 m |
| Default Read Distance | 1.8 m |
| Maximum Read Distance | 2.0 m |

| Specification | Detail |
|---|---|
| Low Detection Range | 1.5 m (bidirectional) |
| Medium Detection Range | 1.0 m (bidirectional) |
| High Detection Range | 0.5 m (bidirectional) |

| Specification | Detail |
|---|---|
| Exit Mode | Sends a single momentary pulse trigger to the receiver upon vehicle detection |
| Presence Mode | Pulses and latches relay, holding the gate open whilst the loop is detecting a vehicle |
| Parking Mode | Same behaviour as Presence Mode; slower latch, slower release, lower power consumption |
| Default Mode | Presence Mode |
| Mode Change Method | Magnetic recess interaction (included magnet) or e-Loop Connect mobile app |
| Specification | Detail |
|---|---|
| EMC Standard | EN 301 489-1 V2.2.3 — ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements; Harmonised Standard for EMC |
| Emissions Standard | EN 55032 — Electromagnetic compatibility of multimedia equipment |
| Specification | Detail |
|---|---|
| Mobile App | e-Loop Connect (available for Android and iPhone) |
| App Functions | Mode change, radar range adjustment, confirmation mode, diagnostics, battery status, signal strength |
| Bluetooth | BLE (Bluetooth Low Energy) for app connection |

| Specification | Detail |
|---|---|
| e-Trans Compatibility | e-Trans 20, e-Trans 50, e-Trans 100, e-Trans 200 |
The e-Loop Light Industrial is designed for quick, straightforward above-ground installation. The following is a summary of the setup process. For complete step-by-step instructions, refer to the Instruction Manual.
Important Installation Warnings: Always install in accordance with the fitment notes in the instruction manual. Failure to do so may void the product warranty. The e-Loop Light Industrial should not be used in Presence Mode as a personal safety device — it is designed exclusively for vehicle detection.
A wireless vehicle detector is a sensor that identifies the presence or movement of a vehicle and transmits a trigger signal wirelessly — without physical wiring — to a receiver or gate controller. The e-Loop Light Industrial uses a combination of radar sensing and magnetometer technology. When a vehicle enters the detection zone, the sensor detects the vehicle's mass and metallic signature, encrypts the trigger signal using 128-bit AES, and transmits wirelessly to the paired e-Trans receiver at 433.39 MHz FSK, which then activates the relay output to open a gate, barrier, or trigger an alert.
Exit Mode sends a single momentary pulse to the receiver when a vehicle is detected — ideal for triggering a gate to open as a vehicle approaches to exit a site. Presence Mode sends a continuous pulse and latches the relay, holding the gate open for as long as the vehicle remains within the detection zone — suited to loading docks and areas where the gate must stay open during vehicle dwell time. Parking Mode is similar to Presence Mode, with a slower latch/release and lower power consumption, making it better suited to parking and storage applications.
No. The e-Loop Light Industrial is completely wireless and battery-powered, requiring no ground cutting, no trenching, and no electrical wiring. It mounts above ground using the included fasteners and communicates wirelessly with compatible e-Trans receivers. This makes it ideal for retrofitting existing driveways, loading docks or factory gates without disrupting the surface or operational flow.
Yes. The EL00LI carries an IP68 ingress protection rating — fully sealed against dust and continuous water immersion — and operates across an extreme temperature range of −40°C to +80°C. This makes it well-suited to Australia's varied climate conditions across all states and territories, including tropical, arid, alpine and temperate zones.
The radar detection system provides a 60° field of view with a default read distance of 1.8 m, a maximum range of 2.0 m, and a minimum read distance of 0.2 m. The magnetometer provides tiered detection sensitivity at 0.5 m, 1.0 m and 1.5 m ranges. Wireless radio transmission range between the sensor and the paired e-Trans receiver depends on site conditions and the selected e-Trans model.
Battery life is influenced by daily activation frequency, activation duration, radar range setting, and environmental conditions. The unit is powered by 4 × 3.6V, 2700 mAh batteries with an extremely low standby draw of just 14 µA. At 50 activations per day, battery life is substantially longer than at higher activation frequencies, such as 300+ per day. The e-Loop Connect app provides real-time battery status diagnostics.
Yes. Mode changes are made in two ways: physically using the included magnet on the sensor's magnetic recesses (no tools required), or remotely via the free e-Loop Connect mobile app for Android and iPhone. The app also enables radar range adjustment, confirmation mode configuration, and access to diagnostics — all without physically interacting with the sensor.
Yes. Once calibrated, the e-Loop requires recalibration whenever it is physically moved to a new location. Recalibration is performed using the included magnet on the SET recess in a simple three-step process. If the sensor is not moved, it will automatically self-calibrate within approximately 5 minutes of being powered on.
The e-Loop Light Industrial pairs with e-Loop's e-Trans receiver range (e-Trans 20, 50, 100 and 200), which provides standard relay outputs for integration with most gate automation controllers, barrier systems, and access control panels commonly used across Australian commercial and industrial sites. Always confirm relay output compatibility with your specific gate controller or automation brand before purchasing.
The EL00LI is suited to a broad range of Australian applications including: driveway exit detection for industrial estates, loading bay presence monitoring, factory perimeter gate automation, service yard entry and exit control, logistics centre vehicle flow management, warehousing gate triggers, mining site access control, rural property gate automation, car park exit detection, and retrofit replacement of failed inductive loop detectors.
The model number is EL00LI. The full instruction manual is available for download in PDF format from Installation Manuals
The e-Loop Light Industrial is tested and certified to EN 301 489-1 V2.2.3 (ElectroMagnetic Compatibility standard for radio equipment) and EN 55032 (Electromagnetic compatibility of multimedia equipment emissions).
No. The e-Loop Light Industrial is designed exclusively for vehicle detection. It must not be used as a personal safety device for pedestrian protection. Presence Mode in particular — which holds a gate open while detecting mass — is not a substitute for safety edges, photocells or other certified personal safety devices required by Australian Standards for automated gate systems.
Wireless access control system for gate and door applications.
Featuring a compact design with exceptional range, the e-Trans-50 is designed to manage access control for home and commercial systems.
A long-range wireless transceiver that can work with both gates and automatic doors. The small design allows it to be easily installed without compromising on the exceptional range.
Voltage: 10-36V DC
Current draw standby: 4.5 m/a
Current draw active: 30 m/a
Frequency: 433.39 MHz
Remote storage: 50 remotes, 4 x e-Loops, 4 x keypads, 4 x entry buttons
Relay: 1-amp contact rating, COM and N/O connections x 1 relay
Modes: Pulse, Latch and Hold
Compact design with an exceptional range
SMA connector standard for external long-range antenna connection
Wide Voltage Range: 10-36V DC
Exceptionally low Current draw: standby 4.5 m/a, active 30 m/a
Frequency: 433.39 MHz
Remote storage: 50 remotes, 2 x Keypads, 2 x Entry Buttons
Relay: 1-amp contact rating, COM and N/O connections x 1 relay
Multiple Modes: Pulse, Latch and Hold